An in-depth analysis of circuit troubleshooting tips for asphalt mixing stations
Release Time:2024-05-31
Read:
Share:
If an asphalt mixing plant wants to maintain normal operation, all aspects of the production process must remain normal. Among them, the normality of the circuit system is an important aspect to ensure its stable operation. Just imagine, if there is a problem with the circuit during the actual construction of the asphalt mixing station, it will affect the progress of the entire project.
For users, naturally we do not want this to happen, so if we are using the asphalt mixing plant and a circuit problem occurs, we must take corrective measures to deal with it in time. The following article will explain this problem in detail, and I can help everyone.
An in-depth analysis of circuit troubleshooting tips for asphalt mixing stations_1An in-depth analysis of circuit troubleshooting tips for asphalt mixing stations_2
Judging from many years of production experience, some malfunctions occur during the work of asphalt mixing stations, usually due to electromagnetic coil problems and circuit problems. Therefore, in actual production work, we must distinguish these two different faults and adopt corresponding solutions to deal with them.
If we check the asphalt mixing plant and find that the fault is caused by the electromagnetic coil, we should first use an electric meter to troubleshoot. The specific method content is: connect the measuring instrument to the voltage of the electromagnetic coil, and measure the actual value of the voltage. If it matches the specified value, it proves that the electromagnetic coil is normal. If it does not match the specified value, we still need to continue to investigate. For example, we need to check whether there are any abnormalities in the power supply and other switching circuits and deal with them.
If it is the second reason, then we also need to judge by measuring the actual voltage. The specific method is: rotate the reversing valve. If it can still turn normally under the specified voltage conditions, then it means there is a problem with the electric furnace and needs to be dealt with. Otherwise, it means that the circuit is normal, and the electromagnetic coil of the asphalt mixing station should be inspected accordingly.
It should be noted that no matter what kind of fault it is, we should ask professionals to detect and deal with it. This can ensure the safety of the operation and also help maintain the safety and smoothness of the asphalt mixing station.